The weird and wonderful world of Non-Newtonian fluids with Simcenter Flomaster
Modelling concrete slurries using Simcenter Flomaster
When fluids don’t follow this rule they are Non-Newtonian. Common examples of these are mayonnaise, custard, honey, toothpaste, paint, blood, shampoo and ketchup. These fluids respond to force non-linearly, this mean that the thickness can change depending on several factors, mainly the force that is applied, the time that it is applied over and the speed that you apply the force.
This behavior is extremely complex and is very rarely accounted for in system simulation during the design phase. This can result in unexpected behaviour of the physical system when it is built. Simcenter Flomaster can be used to accurately model the effects of fluids due to their non-Newtonian nature which results in a close correlation between the two systems.
Background
The graph below shows the different types of fluid behaviour. The Newtonian fluids shows a linear relationship between shear stress and shear rate while Bingham fluids are rigid before suddenly slipping. Dilatant and pseudoplastic behaviours show shear thickening and shear thinning behaviour, these are all complex behaviours that need to be accurately modelled.
Overview
Before looking at an application it is best to understand the fluid behaviour of the concrete slurry that we are investigating. An overview of the Simcenter Flomaster model used to illustrate non-Newtonian fluid behaviour is shown below.
The network consists of two pressure sources, a valve and the non-Newtonian pipe. The fluid flows from left to right and initially both pressures are equal to represent a stationary, zero flow scenario. During the simulation the pressure source on the left slowly increases pressure up to 20 bar.
The purpose of this model is to demonstrate how the concrete slurry behaves very differently to a Newtonian fluid as the pressure is increased. The results of this are shown below, it exhibits dilatant behavior where initially the shear rate increases but the wall shear stress remains near 0 bar. However as the shear rate continues to increase the fluid starts slipping and the shear stress rapidly starts increasing.
Concrete Pumping Truck System
Now that the physics are fully understood we can investigate an application of these fluids. This is a concrete pumping truck that is used to move concrete slurries around a construction site. An overview of the Simcenter Flomaster model used to simulate a concrete pumping truck is shown below.
The system is composed of:
- A reservoir on the left of the schematic, this is used to receive the concrete slurry from a concrete lorry.
- The main pumping assembly, this is inside the pump truck and consists of four cylinders that are all out of phase by 90 degrees to try to ensure a consistent flow. This is connected to a series of short pipes that split the fluid into four cylinders. These all have non-return valves so that the cylinders can’t push the flow in the wrong direction.
- The arm on the right of the schematic. This is used to deliver the concrete slurry to a desired location, this particular truck has been designed to deliver the slurry up to 32.5m horizontally or 35.7m vertically. At the end of this is a nozzle and an outlet.
It is worth acknowledging that a piston pump has been used for two reasons, firstly as was shown in the previous simulations a large amount of force is required to drive the concrete slurry to overcome the shear stress. This couldn’t be achieved with most typical pump designs. Additionally the pulsating flow needed to be captured and its effects on the non-Newtonian fluid.
Results
The first result worth considering is pressure along the length of the arm. The node level pressures must not drop below 1 bar at the highest point and in this scenario the pump is able to provide sufficient pressure. This is shown in the image below where we can see that the minimum pressures are 2.1 bar.
Now that this has been confirmed the pump performance can be analysed. Visually we can only inspect a single point but the whole simulation can be viewed in the tech tips video at the end of this article. Below you can see how cylinder 1 draws in concrete slurry while cylinder 3 is pushing the slurry through the pipe work to the arm to provide a consistent flow.
The cylinders are required to drive the flow but they result in a pulsating fluid flow due to the nature of being a piston pump. This can be seen in the mass flow rate results or alternatively the pressure results. For brevity only the pressure results have been included here but the tech tips video shows this in more detail.
The final plot is the node level pressure at the top of the arm (10m vertical elevation). As mentioned earlier this must not fall below 1 bar and the minimum results were drawn on the schematic above. In this graph we can see the results against time. The pressure peaks at 9 bar when a cylinder is driving maximum flow and pressure. The trough is at 2.2 bar when the machine is in operation.
One final result worth mentioning is the mass flow rate and the fluid velocity. While the mass flow rate seems very high at 4kg/s the velocity is only 0.07 m/s, this is due to the high density of the concrete slurry which is 1442 kg/m3.
Conclusions
In this article, we have seen how to model complex non-Newtonian fluid behaviors and how these can be used to create a concrete pumping truck. The techniques described here could be applied to any non-Newtonian fluid system though. In doing so we have seen how Simcenter Flomaster can be used to front-load system design to understand how a system will behave. If you want to look at this in more detail all of the models used here are included in Simcenter Flomaster as Sample Systems. You can also watch the video below, which guides you through the different steps for setting up and running the model presented in this article along with taking a more in depth look at some of the results.
Watch this demo video to see how to model non-Newtonian fluids using Simcenter Flomaster: Video
This article is repubblished from the Simcenter Blog
What to read next…
What would win in a race, Ice Cream or Apple Sauce?
Article
Remember back to your school days when lunch times were often filled with such philosophical questions as; who would win a fight between a dinosaur and a truck? Or why is.. Continue reading.